Balloon‐expandable transcatheter heart valves for treatment of aortic valve stenosis in patients with large aortic annuli: Evaluation of deployment balloon overfilling strategies

Yvonne Schneeberger, Harun Sarwari, Benedikt Köll, Till J. Demal, Oliver D. Bhadra, Ina von der Heide, Laura Hannen, David Grundmann, Lisa Voigtländer, Lara Waldschmidt, Johannes Schirmer, Simon Pecha, Niklas Schofer, Nils Sörensen, Stefan Blankenberg, Hermann Reichenspurner, Lenard Conradi, Moritz Seiffert, Andreas Schaefer
  • Cardiology and Cardiovascular Medicine
  • Radiology, Nuclear Medicine and imaging
  • General Medicine

Abstract

Objectives

Transcatheter aortic valve implantation (TAVI) using balloon‐expandable (BE) transcatheter heart valves (THV) in aortic annuli above 29 mm includes particular procedural steps, mainly involving overfilling of the deployment balloon. Data on overfilling strategies in clinical daily practice is scarce. We herein aimed for a retrospective description of utilized overfilling strategies in those patients.

Methods

Between January 2016 and December 2022, 45 patients (100% male, 76.9 ± 6.1 years) received TAVI in aortic annuli above 29 mm using a BE THV. Overfilling volumina of the deployment balloon were left to operators' discretion. Clinical and multislice computed tomography data were retrospectively collected. Clinical endpoints were adjudicated in accordance with the updated standardized VARC‐3 definitions.

Results

Profound overfilling (+4/5 mL) was used in patients with a mild calcium burden (˂750 mm³) even in aortic annuli of 29.0–30.0 mm. Nominal/slight overfilling (+1 mL) was used in aortic annuli up to 32.5 mm but an intermediate to severe calcific burden (>750–3200 mm³). Accordingly, a low calcification group (˂750 mm³, n = 17) compared to a significant calcification group (≥750 mm³, n = 28), presented with higher overfilling volumina (2.1 ± 1.4 vs. 0.8 ± 1.0; p ˂ 0.001), although aortic annulus diameter was not different (29.8 ± 0.8 vs. 29.9 ± 0.9 mm; p = 0.7). All‐cause 30‐day mortality was 0%. Device success was 97.8%. Transvalvular mean pressure gradient at discharge was 9.5 ± 3.6 mmHg. No case of PVL >mild was documented.

Conclusion

Extent of overfilling of the deployment balloon largely depends on calcification burden in addition to aortic annulus diameter with significant and profound overfilling particularly in patients with a calcification burden of the aortic valve complex ˂750 mm³.