Simulation Study on Distribution Patterns of Ventilation Flow Field in High-Altitude Tunnels
Bin Zhang, Ruizhe He, Lijun Ma, Yongzai Chang, Shijia Yuan, Yang Liu, Peng Liu, Peng DingTo address the challenges associated with operational ventilation in high-altitude tunnels, this study investigates the distribution patterns of ventilation flow fields and optimizes the spatial layout parameters of jet fans to determine the most effective configuration. Using a case study from the Zhuohe Expressway tunnel, numerical simulations were conducted to analyze four key design parameters: the lateral clear distance (L) between two jet fans in a single group, the vertical distance (H) from the fan center to the tunnel lining, the axial distance (T) from the fan to the tunnel entrance, and the longitudinal spacing (S) between two groups of fans. The results indicate that for a single-fan group, when the parameter L is 1.25D (D is the fan diameter), pressure rise and comprehensive influence coefficients reach peak values of 20.090 Pa and 0.886, respectively. As well as the parameter H between 1.20 m and 1.25 m, the diffusion of the vertical wind field velocity is continuously reduced due to the constraint of the tunnel lining on Section BB of the tunnel fan’s symmetry axis, and the interference of the tunnel lining on the stable flow state of the fan’s outlet airflow is relatively small. Moreover, parameter T has a relatively low sensitivity impact on the increase in pressure and the variation of the influence coefficient. When the parameter T is within the range of 50 m to 100 m, the airflow at the entrance of the tunnel is smoothly connected with the airflow at the suction section of the fan. Additionally, the pressure rise and the influence coefficient increase by the parameter T. Both the fan’s pressure rise and the influence coefficient reach their maximum values when the parameter T is 100 m. Furthermore, in the case of two-fan groups, the gas is fully mixed in the tunnel when the parameter S is 150 m, and the fan pressure rise and the influence coefficient increase as well as parameter S. The gas between the two sets of fans has been fully mixed in the parameter S at 175 m, and the pressure rise and the coefficient influence reach their maximum values of 40.231 Pa and 0.887, respectively. In light of these findings, the following optimal parameters ranges are recommended for similar tunnel ventilation designs: parameter L is 1.25D for two jet fans within a single group, parameter H is between 1.20 m and 1.25 m, parameter T is 100 m from the tunnel entrance, and parameter S is between 150 m and 175 m for two groups of fans.