DOI: 10.3390/buildings16163176 ISSN: 2075-5309

Seismic Performance Test and Finite-Element Analysis of T-Shaped Steel Plate Connection for Strengthening Reinforced Concrete Beam–Column Joints

Jian Wu, Changhao Wei, Shi’en Zhang, Chunjuan Zhou, Chaoqun Hu, Weigao Ding

To enhance the seismic performance of existing reinforced concrete (RC) buildings during retrofitting, the study introduces a new type of joint connected by a T-shaped steel plate. Compared with previous similar strengthening methods, this novel structure incorporating a post-installed beam not only effectively improves the mechanical properties of RC columns, but the connectors also further enhance the integrity of the post-installed beam. Low-cycle reversed loading tests on one cast-in-place specimen (RC) and three T-shaped steel plate connection specimens (TRC1–TRC3) were conducted to evaluate failure modes, hysteresis and skeleton curves, and energy dissipation. Results show that the novel joint failure concentrates at beam-end–column steel jacket weld seams and column-side steel plate cracking, while the core-zone concrete remains intact. Compared with RC, the novel joints TRC1–TRC3 exhibit bearing capacity variations of −1.03%~+15.80% and significantly enhanced energy dissipation. The thickness of the beam’s wrapped steel improves the carrying capacity and energy dissipation, whereas the T-shaped connector thickness has limited influence on bearing capacity. ABAQUS parametric analysis indicates that bolt quantity, concrete strength, and connector thickness have limited influence and serve as secondary design factors. These findings provide a theoretical basis for retrofitting existing buildings.