Multimethod Evaluation of the Novel Reciproc Minima System: Geometric Design, Mechanical Performance, and Irrigation Dynamics
Emmanuel J. N. L. Silva, Jorge N. R. Martins, Victor T. L. Vieira, Mário Rito Pereira, Ricardo Pinto, Murilo P. Alcalde, Marco A. H. Duarte, Duarte Marques, Marco A. VersianiObjectives: To compare the geometric design, metallurgical properties, mechanical performance, and irrigation dynamics of Reciproc Minima (M20 and M25) and Reciproc Blue R25 instruments. Methods: One hundred and eighty instruments (n = 60/group) were evaluated. Geometry was analyzed using stereomicroscopy, scanning electron microscopy, and 3D surface scanning. Metallurgical characteristics were assessed by energy-dispersive X-ray spectroscopy and differential scanning calorimetry. Mechanical performance tests (n = 10/group) included cyclic fatigue, torsional resistance, bending resistance, buckling resistance, and cutting efficiency. Irrigation dynamics were examined through computational fluid dynamics simulations based on a micro-CT-derived mandibular molar model prepared according to each system and combined with open-ended, side-vented, or double side-vented needles. Data were analyzed using one-way ANOVA or Kruskal–Wallis tests (α = 0.05). Results: The results showed that blade dimensions increased progressively from Minima M20 to Reciproc Blue R25. All instruments had S-shaped cross-sections and non-active tips. Energy-dispersive spectroscopy confirmed near-equiatomic NiTi composition, and similar phase transformation temperatures were observed across groups. Minima M20 showed the highest cyclic fatigue resistance (p < 0.0001), whereas Minima R25 exhibited greater angular deflection (p < 0.0001). Reciproc Blue R25 had the highest buckling resistance and lowest flexibility (p < 0.0001). M25 showed the lowest axial force, indicating the numerically highest cutting efficiency, but it did not differ significantly from Reciproc Blue R25 (p > 0.05). No needle delivered irrigant to working length. The open-ended needle achieved greater apical penetration, particularly with Reciproc Blue R25. Minima M20 generated the highest wall shear stress, and Reciproc Blue R25 the lowest apical pressure. Conclusions: Reciproc Minima and Reciproc Blue R25 showed similar metallurgical characteristics; however, differences in geometric design resulted in distinct mechanical behaviors and irrigation fluid dynamics. These findings suggest that low-taper reciprocating instruments may represent a conservative alternative in anatomically challenging canals, while clinicians should consider the associated differences in mechanical behavior and irrigation dynamics when selecting the most appropriate instrument.