MRI-Compatible Ex-Vivo Tensile Testing for Assessment of Passive Mechanical Properties of Whole Muscle
Iraj Dehghan-Hamani, Alexander Burden, Stephen H. M. Brown, Thomas R. OxlandAccurate measurement of the passive mechanical properties of whole skeletal muscle is essential for physiological studies and biomechanical models. However, conventional ex-vivo tensile testing to measure these properties often relies on assumptions for stress and strain calculation. Specifically, strain is typically calculated from grip-to-grip displacement, and stress is found using muscle physiological cross-sectional area (PCSA) based on literature density values. This study aimed to develop a method directly quantifying muscle 3D geometry during stretching to measure its passive elastic modulus. Our MRI-compatible ex-vivo tensile testing framework integrated stepwise testing with high-field (9.4T) MRI. This enabled us to directly quantify whole-muscle 3D geometry, volume, and length during stretching. Ten rat tibialis anterior muscles underwent incremental lengthening (∼6% strain per step) with 4-min stress-relaxation holds while acquiring T2-weighted 3D MRI at each step. Engineering stress-strain data were calculated using MRI-based and conventional measurements. Grip-to-grip strain overestimated muscle strain by 13.7% compared to MRI-derived value, while considering MRI-based volumetric PCSA produced stresses 7.4% higher than the traditional gravimetric approach. These methodological differences increased the estimated passive elastic modulus by ∼40% versus conventional calculations. We also observed progressive muscle volume increases during testing (∼13.7% from slack length to ∼36% strain), with larger baseline volumes in specimens stored longer in Tyrode’s solution. Accounting for this volume change, true stress–strain results showed substantially higher modulus values than engineering estimates (1162 ± 519 vs. 745 ± 352 kPa at 30% strain). Overall, MRI-based geometry monitoring improved whole-muscle stress–strain characterization and revealed muscle volume increases during ex-vivo testing.