Improving Speed and Efficiency of DESI Imaging with the Xevo MRT Mass Spectrometer for Analyte Mapping

Mark Towers, Emmanuelle Claude, Lisa Towers, Helen Yates, Joanne Ballantyne

Background: Recent technology improvements have enabled desorption electrospray ionisation (DESI) mass spectrometry imaging to achieve down to 5 µm (pixel) image resolution. However, operating at this resolution introduces challenges, particularly regarding increased total analysis time and the need for sufficient instrument sensitivity to detect analytes from very small tissue areas. Methods: High mass and image resolution DESI imaging was performed on rat brain tissue using a Xevo™ MRT benchtop mass spectrometer equipped with a multi-reflecting time-of-flight mass analyser and a DESI XS source. Data acquisition was conducted at speeds of up to 100 Hz. Sensitivity was assessed using a dilution series of five Active Pharmaceutical Ingredients (APIs) spotted onto porcine liver tissue. Signal detection limits were evaluated using extracted ion chromatograms (XICs) with signal-to-noise (S/N) calculations against blank samples. Additionally, enhanced duty cycle (EDC) was applied to evaluate improvements in analyte signal intensity across specific mass ranges in both positive and negative ionisation modes. Results: At acquisition speeds of up to 100 Hz, excellent data quality was achieved, with signal intensity remaining suitable for analytical applications. All five tested APIs were detectable at concentrations of 25 pg/mm2. Three of the five compounds were further detected at concentrations as low as 2.5 pg/mm², with signal-to-noise ratios greater than 5. The application of EDC resulted in a significant increase in analyte signal intensity within the targeted mass ranges, particularly for small molecule endogenous metabolites and lipids, in both ionisation modes. Furthermore, the system demonstrated substantially improved spectral quality, achieving mass resolution up to 100,000 FWHM. This enabled the resolution of previously indistinguishable analytes with significantly improved mass accuracy compared to systems operating at approximately 30,000 FWHM. Conclusions: The Xevo™ MRT mass spectrometer with DESI XS source enables high-resolution DESI imaging at speeds up to 100 Hz without compromising data quality or sensitivity. The system demonstrates excellent detection limits for pharmaceutical compounds and improved performance through enhanced duty cycle operation. Overall, the combination of high spatial resolution, increased mass resolution, and improved spectral quality allows for more accurate analyte differentiation, representing a significant advancement over lower-resolution systems.

More from our Archive