Heat-to-Power Matching Constraints in Residential PEMFC Cogeneration: Implications for Dispatch and Electrolyzer Sizing
Tiancheng Fang, Jiwei Wang, Honghao Wang, Baoyi Shen, Zhenyan Ma, Yingliang Yang, Yun Duan, Jingxuan Yang, Guoqing Guan, Abuliti AbudulaResidential fuel cell cogeneration is usually credited with all its recovered heat, although that heat is useful only if a coincident demand absorbs it. Hourly TRNSYS 18 simulations of an off-grid dwelling in Aomori City, Japan, with a 700 W proton exchange membrane fuel cell running on self-produced hydrogen, compared four dispatch rules, two thermal services and several electrolyzer and store sizes over a periodic year. With space heating, residual heat demand was 12.6 times the electrical deficit after photovoltaic and battery supply. The unit was potentially heat-rich in 88.7–92.3% of deficit hours with hot water alone and 2.2–3.7% with space heating. Against a run without hydrogen, 25–61% of the heat an immersed coil delivered to the store reduced unmet thermal demand where the cycle closed; 22–54% displaced solar heat and 15–22% raised tank losses. Under calendar dispatch with hot water alone, 75% of recovered heat could not pass the coil. Load following raised self-sufficiency from 88.9% to 96.3%, whereas calendar dispatch, and thermally led dispatch with space heating, needed 2.8–5.0 times the producible hydrogen. Electrode areas of 40–110 cm2 gave identical service; each Nm3 of storage was below the seasonal swing of 76.7 Nm3 cost 1.77 kWh of output.