False-Positive Acanthamoeba Keratitis From Multiplex Polymerase Chain Reaction Diagnostics, a Case Series
Alejandro Arboleda, Ashlin Joye, Daniel Goodman, Matthew R. Denny, Thuy Doan, Gerami D. SeitzmanPurpose:
The purpose of this study was to describe a series of cases in which multiplex polymerase chain reaction (PCR) suggested false-positive
Methods:
Four patients without traditional risk factors for AK were referred after multiplex PCR (HealthTrackRx, Denton, TX) returned positive for
Results:
Three patients had corneal involvement, and 1 had anterior scleritis without any corneal pathology. In all cases, corneal cultures were negative for
Conclusions:
These cases illustrate the potential for false-positive multiplex PCR results for