DOI: 10.1111/jerd.13473 ISSN: 1496-4155

Evaluation of Polymerization Shrinkage, Microhardness, and Depth of Cure of Different Types of Bulk‐Fill Composites

Sergen Özdemir, İlker Ayaz, Nurgül Çetin Tuncer, Çağatay Barutçugil, Ayşe Dündar

ABSTRACT

Objectives

This study aimed to quantify polymerization shrinkage, microhardness, and depth of cure of different types of bulk‐fill composites.

Methods

Six bulk‐fill composites were tested: SonicFill 2 (SCF), VisCalor (VVC), Admira Fusion x‐tra (AFX), Filtek Bulk Fill (FBF), Fill‐Up! (FUP) and GrandioSO Heavy Flow (GHF). Sixty teeth were divided into twelve groups (n = 5) according to the composite and the irradiation level applied (standard or high). Each tooth was subjected to three scans using a micro‐computed tomography device. The microhardness of the composite specimens was measured using a Vickers hardness tester. Depth of cure analysis was performed by measuring the microhardness of the composites at 0.5 mm intervals from the top surface to the bottom surface.

Results

The highest volumetric shrinkage was found in the AFX group when polymerized at standard irradiance. After curing, the AFX group showed the highest void ratio. Increasing irradiance significantly increased volumetric shrinkage and void ratio only in the SCF group (p < 0.05). GHF achieved the maximum microhardness value of 80% at the lowest curing depth of 2.9 mm, while VVC, AFX, and SCF showed a curing depth of more than 5 mm (p < 0.05).

Conclusions

The high irradiance caused the most significant volumetric shrinkage and void ratio in the SCF group. Only the FUP and GHF groups were unable to achieve the desired curing depth of 4 mm.

Clinical Relevance

Irradiance, material types, and thickness are important factors in the polymerization of composites.