Evaluation of a hybrid protocol using continuous glucose monitoring and point-of-care testing in non–critically ill patients in a community hospital
Matt Baker, Sara Lauterwasser, Catherine Valenti, Michael Kallenberger, Haleigh Stolte- Health Policy
- Pharmacology
Abstract
Disclaimer
In an effort to expedite the publication of articles, AJHP is posting manuscripts online as soon as possible after acceptance. Accepted manuscripts have been peer-reviewed and copyedited, but are posted online before technical formatting and author proofing. These manuscripts are not the final version of record and will be replaced with the final article (formatted per AJHP style and proofed by the authors) at a later time.
Purpose
Inpatient glycemic management typically involves use of point-of-care (POC) glucose measurements to inform insulin dosing decisions. This study evaluated a hybrid monitoring protocol using real-time continuous glucose monitoring (rtCGM) supplemented with POC testing at a community hospital.
Methods
Adult inpatients receiving POC glucose testing were monitored using rtCGM in a telemetry unit. The hybrid monitoring protocol required a once-daily POC test but otherwise primarily relied on rtCGM values for insulin dosing decisions. Outcomes assessment included surveillance error grid (SEG) and Clarke Error Grid (CEG) analysis results, the mean absolute relative difference (MARD) for available rtCGM-POC value pairs before and after study protocol application, the number of POC tests avoided, and the number of hypoglycemic events involving a blood glucose value of <70 mg/dL identified by rtCGM and POC values.
Results
Data were collected from 30 inpatients (the mean age was 69.4 years, 77% were female, 80% had type 2 diabetes, and 37% were at-home insulin users). With the protocol applied, a total of 202 rtCGM-POC pairs produced a MARD of 12.5%. SEG analysis showed 2 pairs in the “moderate” risk category, with all other pairs in the “none” or “slight” risk categories. CEG analysis showed 99% of paired values to be in the clinically acceptable range. Six hypoglycemic events in 5 patients were resolved without incident. Three hundred three POC tests were avoided, a 60% reduction for the study duration.
Conclusion
Use of a hybrid monitoring protocol of rtCGM and POC testing in a community hospital demonstrated sustained rtCGM accuracy and was found to reduce the frequency of POC testing to manage inpatient glycemia.