DOI: 10.1177/17085381231192731 ISSN: 1708-5381

Endovascular treatment of re-stenotic iliac artery stents with drug-eluting balloons

Halil Berkan Özpak, Cihan Aydın
  • Cardiology and Cardiovascular Medicine
  • Radiology, Nuclear Medicine and imaging
  • General Medicine
  • Surgery

Aim

To evaluate the results of revascularization of stenotic iliac stents using drug-eluting balloons (DEBs).

Material and Methods

Seventy-four patients with various levels of iliac stent restenosis were enrolled to study. All restenotic stents were treated using paclitaxel-coated balloons.

Results

Through a follow-up median period of 24 months (4–24 months), there were no in-stent re-restenosis in 55 patients (74.3%) and there was one in class 1 (1.4%), four in class 2 (5.4%), and fourteen in class 3 (18.9%).

Conclusion

We conclude that; DEBs can be used for restenotic iliac artery stents for some Type C and D lesions, in addition to Types A and B with satisfacting results.

More from our Archive