Effect of Crown Height Space and Abutment Configuration on the Maximum Recorded Load of Implant-Supported Monolithic Zirconia Crown Assemblies
Özay Özsoy, Melek Nur Ürün, Şeyda Bektaş, Serdar PolatThis in vitro study evaluated the effects of crown height space (CHS) and abutment configuration on maximum recorded load and described post-test damage in implant-supported monolithic zirconia crown assemblies. Sixty specimens were assigned to six groups (n = 10) combining Ti-base or multi-unit configurations with nominal CHS levels of approximately 13.5, 15.5, or 17.5 mm. After 200,000 thermomechanical aging cycles at 50 N with thermal cycling between 5 °C and 55 °C, specimens underwent eccentric vertical loading on the buccal incline of the functional cusp using a 4 mm spherical tip at 1 mm/min. The primary outcome was maximum recorded load (global peak load), not the onset of irreversible damage. Two-way ANOVA indicated a CHS effect (p = 0.012), but no significant effect of abutment configuration (p = 0.128) or interaction (p = 0.627). The CHS effect persisted in the HC3 analysis (p = 0.043). The lowest versus highest CHS comparison remained significant in heteroscedasticity-sensitive analyses; the lowest-versus-intermediate comparison depended on analytical approach. Four zirconia crown fractures occurred in the lowest-CHS Ti-base group; other post-test damage predominantly involved prosthetic connection components. Within these laboratory conditions, CHS influenced assembly-level maximum recorded load without establishing a continuous or linear relationship.