DOI: 10.1093/eurheartj/ehag785.1459 ISSN: 0195-668X

Diagnostic performance and 3-month prognostic impact of multimodal assessment of residual congestion at discharge in acute heart failure

A Torrelles, M Domingo, E Zamora, M Soler, G Romero, E Barcelo, B Ochoa, A Caballero, M Maymi, R Vila, G Guix, X Garcia, C Pacho, C Tural, A Bayes-Genis

Abstract

Background

Residual congestion at discharge is common in patients hospitalized for heart failure (HF) and is strongly associated with early post-discharge adverse outcomes. Despite its clinical relevance, detection of residual congestion remains an unmet need, as several clinical, device-based, and biomarker tools are available, yet it is unclear which approach best identifies residual congestion and provides prognostic value.

Purpose

The aim of this study was: (1) to evaluate the diagnostic performance of bedside ultrasound, including lung ultrasound (LUS) and venous excess ultrasound (VExUS), remote dielectric sensing (ReDS), bioimpedance, and NT-proBNP for the detection of residual congestion at hospital discharge compared with clinical assessment; and (2) to assess the association between residual congestion detected by each method and 3-month adverse outcomes in patients hospitalized for HF.

Methods

This was a prospective, single-centre study including consecutive patients hospitalized for HF, either with de novo HF or decompensated chronic HF. At discharge, congestion was assessed using ultrasound (LUS and VExUS), clinical scores [Composite Congestive Score (CCS) and EVEREST score], ReDS, bioimpedance, and NT-proBNP. The results of ultrasound, ReDS, and bioimpedance assessments were blinded to the treating physicians. Residual congestion at discharge was defined for each modality. The primary endpoint was a composite of all-cause mortality, HF hospitalization, and urgent HF visits requiring intravenous diuretics at 3 months (cEP3).

Results

A total of 233 patients were included (mean age 70.6 years, 64.4% men, 61.4% with de novo HF, mean left ventricular ejection fraction 42.6%, and mean discharge glomerular filtration rate 55.9 mL/min). At 3 months, cEP3 occurred in 24.9% of patients (n=58).

Residual congestion at discharge was detected in 46.4% of patients by ultrasound (LUS and VExUS), compared with 9.0% by CCS, 20.6% by EVEREST, 31.7% by ReDS, 78.8% by bioimpedance, and 47.7% by NT-proBNP. Concordance among methods was low (Cohen’s kappa <0.6). Ultrasound showed the highest sensitivity (79%) and negative predictive value (90%) for predicting cEP3 (Table 1). The highest discriminative ability was also observed with ultrasound (AUC 0.72, 95% CI 0.66–0.78) (Table 2). Residual congestion detected by ultrasound was associated with the strongest prognostic impact (OR 6.99, 95% CI 3.54–14.72; p<0.0001) (Table 3).

Conclusion

Residual congestion at discharge is common in patients hospitalized for HF and remains a major determinant of early post-discharge adverse outcomes. Ultrasound-based assessment (LUS and VExUS) outperforms clinical, other device-based, and biomarker approaches for detecting residual congestion and provides superior prognostic stratification at 3 months. These findings support the integration of ultrasound-based congestion assessment at discharge into routine clinical practice.

More from our Archive