Design of Resilient Renewable-Fed Microgrid Using ANFIS-Based MPPT Control and Adaptive Power Management with Voltage Stability Enhancement
Mohammad Kamruzzaman Khan Prince, Md. Rimon Hossain, Md. Rashedul Islam, Saeed Ahamed Mridha, Md. Salah Uddin, Md. Feroz Ali, Md. Shafiul Alam, Shama Islam, Mohammad Taufiqul ArifThis paper presents the design, control, and validation of a solar photovoltaic (PV)-powered DC microgrid (MG) integrated with a battery energy storage system (BESS), which was studied at laboratory scale as a step towards remote electrification in resource-constrained regions. An Adaptive Neuro-Fuzzy Inference System (ANFIS)-based maximum power point tracking (MPPT) algorithm is implemented to maximise solar energy extraction under varying irradiance. An Adaptive Power Management (APM) framework is proposed to maintain DC bus stability when the BESS is unavailable to support the bus—a condition that may arise from battery degradation, sensor or communication failures, converter malfunctions, protection trips, or physical damage. In this work, BESS unavailability is represented at the system level as the withdrawal of BESS support; the individual fault mechanisms that may cause it are not separately modelled. The APM operates across three hierarchical layers—monitoring, decision, and control—and reuses only the voltage and current measurements already present in the MG, requiring no additional sensing. The system is evaluated under three operating scenarios: (i) intermittent renewable generation; (ii) varying load demand; (iii) stochastic fluctuations in both irradiance and load. During BESS unavailability, the APM activates prioritised adaptive load shedding or PV generation curtailment as appropriate, preserving critical loads and preventing DC bus overvoltage. In the scenarios studied, the APM reduces worst-case voltage sag from 35.9% to 2.4% and worst-case swell from 53.51% to 0.14%, while maintaining BESS State of Charge (SOC) within 20%–80% during normal operation. Compared with the conventional Perturb and Observe (P&O) and Incremental Conductance (INC) methods, the ANFIS-based MPPT achieves a mean point-wise tracking and conversion efficiency of 99.46%, a 1.78% improvement and a 0.86% improvement, respectively, which were corroborated by independent energy-based assessments (1.76% and 0.92%), with voltage deviations of 2.34% and oscillations of only 0.57 V peak-to-peak. Lyapunov-based analysis establishes asymptotic stability of the DC bus voltage in the BESS-regulated operating modes under stated assumptions. The proposed control strategies are validated through MATLAB/Simulink (R2025b) simulations and laboratory-scale experimental results, with the latter demonstrating coordinated PV–BESS–converter operation and bus voltage regulation.