Design and development of air ventilated air bed for hospitalized patients
Darshan KARANJE, Shivroop PATIL, Shivraj GURSAL, Prafulla HATTE - Fluid Flow and Transfer Processes
- Energy Engineering and Power Technology
- Building and Construction
Proper ventilation is a critical consideration for the comfort of hospitalized patients. Dry skin, skin rashes, weariness, poor sleep, and other concerns caused by insufficient ventilation can all be avoided with proper ventilation. Air-Ventilated Air Beds are used to supply air to the major parts of the patient’s body. This air bed is constructed in such a way that air is circulated con-tinually throughout the body of the hospitalized patient. It is especially beneficial for people who are bedridden and need to spend a significant amount of time in bed due to illness. Exces-sive heat generated between the bed and the patient is perhaps the common cause of bedsores. Sweating is the leading cause of bedsores. Air ventilation is included in the system to prevent sweating and reduce the incidences of bedsores. Dual compressors, rubber tubes, flow control valves, and anti-decubitus mattresses are among the components used. The rubber tubes are used to ventilate the space between the body of the patient and the upper surface of the air bed. Above the mattress, the rubber tube mesh is positioned. The air is first compressed in two compressors before passing through the distribution manifold and through the meshing. The tubes are altered by drilling holes at certain intervals. The air from the compressor is circulated through the pipes before passing through the openings in the pipes. The unrestricted passage of compressed air via a capillary tube lowers the temperature of the air. The air exhausted through the capillary tubes maintains the patient’s body temperature stable for a while before lowering it. The air is ventilated throughout the bed in this manner. Bedsore can be avoided by reduction of sweat by using the air in close contact with the patient.
More from our Archive
-
DOI: 10.1063/5.0170506 2023
Oceanic shallow-water investigations on a generalized Whitham–Broer–Kaup–Boussinesq–Kupershmidt system Xin-Yi Gao
-
DOI: 10.3390/app132312946 2023
A Multivariate Time Series Analysis of Electrical Load Forecasting Based on a Hybrid Feature Selection Approach and Explainable Deep Learning Fatma Yaprakdal, Merve Varol Arısoy
-
DOI: 10.1063/1.869966 2002
Direct numerical simulation of turbulent channel flow up to Reτ=590 Robert D. Moser, John Kim, Nagi N. Mansour
-
DOI: 10.1063/1.869307 2002
On pressure and velocity boundary conditions for the lattice Boltzmann BGK model Qisu Zou, Xiaoyi He
-
DOI: 10.1063/1.859529 2002
Influence of sheared poloidal rotation on edge turbulence H. Biglari, P. H. Diamond, P. W. Terry
-
DOI: 10.1063/1.869828 2002
The formation and evolution of synthetic jets Barton L. Smith, Ari Glezer
-
DOI: 10.1063/1.3456626 2010
Review Article—Dielectrophoresis: Status of the theory, technology, and applications Ronald Pethig
-
DOI: 10.1063/1.2717527 2007
Hairpin vortex organization in wall turbulence Ronald J. Adrian
-
DOI: 10.1063/1.1399290 2002
Momentum transfer of a Boltzmann-lattice fluid with boundaries M’hamed Bouzidi, Mouaouia Firdaouss, Pierre Lallemand
-
DOI: 10.1063/1.868850 2002
Capillary effects during droplet impact on a solid surface M. Pasandideh-Fard, Y. M. Qiao, S. Chandra, J. Mostaghimi