DOI: 10.3390/s26123943 ISSN: 1424-8220

Cross-View Measurement of Adjacent Fastener Bolt Spacing in Railway Turnouts Using Dual DLP Sensors Without Overlapping Fields of View

Yuntao Gou, Le Wang, Zhixiong Hou, Huchao Zhai, Zichen Gu, Qiyong Wu, Hao Wang, Ning Wang, Qiang Han, Fadeng Wang

To measure the cross-view spacing between adjacent fastener bolts in railway turnouts, this study develops a dual-DLP-sensor structured-light measurement system without overlapping fields of view. A bridge-type calibration device is used to rapidly update the extrinsic parameters of the two DLP sensors. In a unified coordinate frame, the system integrates two-dimensional region-of-interest candidate generation, local three-dimensional geometric fitting, cross-view pairing, and measurement validity assessment to output bolt-spacing results. Experiments were conducted on 23 pairs of adjacent bolts with 15 repeated measurements using two DLP sensors. Under normal conditions, the mean absolute error, root mean square error, and average standard deviation were 0.261 mm, 0.290 mm, and 0.062 mm, respectively. Compared with fixed extrinsic parameters without updating, the bridge-based extrinsic update reduced the mean absolute error from 1.500 mm to 0.261 mm. The results indicate that the proposed task-driven dual-DLP-sensor measurement system can achieve stable cross-view spacing measurement with explicit validity criteria under non-overlapping fields of view, repeated deployment, and varying on-site data quality.