DOI: 10.68482/prj.1993.5.003 ISSN: 3079-8493
CORROSION CONTROL IN DEFA WATERFLOOD SYSTEM
M.A. ElarabiPractical methods are presented to select different biocides and corrosion inhibitors for the DEFA water-flood system. It involves the use of side stream bacteria detection on mounted probes and potentiodynamic technique on the well head of a source water well. These methods are well suited for application in systems where high frequency fluctuations in process variables are encountered. Field examples of corrosion problems and solutions are cited.