Comparison of blind end closure techniques in equine ileum
Rachel L. Hilliard, Amanda Prisk, Sichao Wang, Stefanie Hansen, Amelia MunstermanAbstract
Objective
To determine the difference in bursting pressure (BP), bursting wall tension (BWT), and closure speed between commonly utilized methods of ileal stump closure.
Study design
Randomized experimental study.
Sample population
A total of 71 ileal segments from 18 healthy horses.
Methods
Ileum was collected postmortem from 18 horses and divided into four segments. One end of each segment was closed using one of three techniques: Parker‐Kerr (PK), gastrointestinal staples (ST), or gastrointestinal staples with a Lembert staple oversew (SO). Closure time was recorded. Control (C) segments were not altered. Segments were distended until failure. BP and infusion volume were documented, and BWT was calculated.
Results
Conclusion
No difference in BP or BWT was observed between closure techniques in healthy ileum. ST and SO were significantly faster than PK.
Clinical significance
The similarity in bursting strength across techniques suggests that closure method should be chosen based on other factors. The ST closure was faster compared to other techniques, and the addition of an oversewing pattern did not improve security of closure.