DOI: 10.1063/5.0348812 ISSN: 0034-6748

Coincidence counting of double-shell shot solid debris

G. Rusev, A. S. Crowell, S. W. Finch, C. Fry, A. C. Hayes, D. Lonardoni, E. N. Loomis, J. D. Martin, S. D. Nolen, S. Palaniyappan, A. P. D. Ramirez, W. Tornow, A. B. Weberg, J. M. White

In support of Los Alamos National Laboratory’s double shell program and the radiochemical diagnostic of mix, a study of the coincidence γ rays was carried out at the tandem accelerator of the Triangle Universities Nuclear Laboratory. A tungsten foil was irradiated with 13 MeV deuterium beams, and coincidence γ rays with multiplicity up to five were observed with a dual high-purity germanium detector system. The level schemes of 182W and 184W were constructed from the identified coincidence γ rays. Many of these γ rays were confirmed by coincidence counting of two solid radiochemical collection diagnostic foils from a recent tungsten-capsule double shell shot N260124 at the National Ignition Facility. Measuring the decay curve of the tungsten characteristic γ rays revealed a new model-independent method for estimating the effect of mix.

More from our Archive