CFD-Based Simulation and Optimization of Summer Environmental Conditions in Laying Hen Houses
Lili Zhang, Shanjie Zhang, Miaomiao Xie, Jun Li, Xianwang Liu, Zhirun Ma, Qiang Zhang, Hualong LiTo address uneven temperature and relative humidity distributions, localized heat accumulation, and insufficient air velocity in an enclosed stacked-cage laying hen house, a three-dimensional computational fluid dynamics (CFD) model of the laying hen house was developed using field-measured structural and environmental data, and a porous-media model was established for the cage zone. Model validation showed that the normalized mean square error (NMSE) values for temperature, relative humidity, and air velocity were all below 0.25, confirming the reliability of the CFD model. Through visualization analysis of the contour maps, the problems of uneven airflow distribution in the original ventilation system and significant heat accumulation at the fan end were identified. On this basis, numerical simulations were conducted for six air-inlet configurations by varying two key parameters: air-inlet spacing and air-inlet number. The simulation results showed that, compared with the original model, the configuration with an air-inlet spacing of 1.14 m and a total of 32 air inlets on the two gable walls improved the uniformity of temperature, air velocity, and relative humidity by 18.00%, 10.54%, and 18.38%, respectively, while reducing the mean effective temperature index (ETI) in the cage zone by 0.5 °C. This configuration effectively alleviated localized heat accumulation and improved air-velocity uniformity. These findings provide a theoretical basis and technical support for the structural optimization and environmental regulation of enclosed stacked-cage laying hen houses.