Carbon-Emission Analysis of a Liquefied Natural Gas Regasification System Using Power-Plant Thermal Discharge
Wanju Sun, Tao Luan, Pengliang Zuo, Xiaolei Si, Hongyan Zhao, Zheng Cai, Xu Yan, Siyuan Cheng, Yingjun Guo, Hexu SunLow seawater temperatures constrain the operation of open rack vaporizers (ORVs) and intermediate fluid vaporizers (IFVs), while also increasing pumping-related emissions at LNG terminals. This study establishes a carbon-oriented framework for an expanded ORV–IFV regasification system sharing a fixed-speed seawater pump network and evaluates thermal discharge from an adjacent power plant as a supplementary heat source. Using measured LNG composition, we developed an Aspen HYSYS model based on the Peng–Robinson equation of state and steady-state energy balances, which was validated against field data. Electricity-related CO2 emissions from seawater pumps and auxiliaries were quantified using the regional grid emission factor, while pump scheduling was formulated as a mixed-integer nonlinear programming (MINLP) problem. Model predictions differed from measurements by approximately 2%. Lower seawater temperatures increased emissions and restricted maximum regasification capacity to 80% and 57% of the design value at 3–4 °C and 2–3 °C, respectively. For LNG throughputs of 300, 500, and 700 t/h, CO2 reduction increased with warm-seawater flow and inlet temperature; maximum reductions reached approximately 50–55% under 3–7 °C ambient seawater conditions and 40% under 6–20 °C conditions, with a 95% confidence interval of ±3.9 percentage points. Monthly discharge data indicated reductions of approximately 20% in winter and 45% in summer. Integrating power-plant waste heat with load-dependent pump scheduling can improve the carbon performance of LNG regasification.