DOI: 10.1177/15266028261502671 ISSN: 1526-6028

Bare-Metal vs Covered Balloon-Expandable Stents for Transplant Renal Artery Stenosis: A Retrospective Comparative Study

Andrea Discalzi, Enrico Sanna, Maria Antonella Ruffino, Matilde Mandolini, Floriana Nardelli, Jacopo Brino, Thaira Albarello, Caterina Tallia, Marco Calandri, Luigi Biancone

Purpose:

To compare short- and long-term outcomes of bare-metal (BMS) vs covered (CS) balloon-expandable stents in transplant renal artery stenosis (TRAS).

Materials and Methods:

This retrospective study evaluated patients who underwent elective stent placement for TRAS between 2016 and 2023. Short-term efficacy was assessed by clinical improvement (resolution of resistant hypertension/hypervolemia) and reduction in serum creatinine (sCr) within 14 days post-procedure. Long-term outcomes included Doppler ultrasound parameters – peak systolic velocity (PSV), acceleration time (AT) and resistive index (RI) – and restenosis/occlusion rates requiring or not intervention. Graft survival at the latest follow-up was recorded.

Results:

A total of 40 patients (mean age 58 ± 13 years, 68% male) were treated with BMS (n = 31) or CS (n = 9). Clinical improvement was observed in 71% of BMS and 83% of CS patients ( P  = 1.00). Median sCr decreased by 26% and 33% in BMS and CS patients, respectively ( P  = .30). At a median follow-up of 29 months, there were no statistically significant differences between groups in median PSV reduction (47% BMS vs 47% CS; P  = .44), AT improvement (36% BMS vs 25% CS; P  = .38) or RI increase (15% BMS vs 33% CS; P  = .12). In the BMS group, 2 cases of in-stent restenosis occurred (6.5%). In the CS group, 1 stent occlusion occurred (11%), resulting in graft loss. At final follow-up, overall graft survival was 85%.

Conclusion:

In this pilot study, BMS and CS showed no significant differences in TRAS outcomes. Further studies are warranted to better guide stent selection.

Clinical Impact

In transplant renal artery stenosis, balloon-expandable covered stents achieved clinical, biochemical and Doppler outcomes comparable to bare-metal stents, despite being used in more complex, atherosclerotic and longer lesions. This first direct comparison suggests that covered stents may be a reasonable option when heavy calcification, a friable wall or mural thrombus raise concern for embolisation or rupture, while bare-metal stents remain appropriate for most lesions. The single late covered-stent occlusion with graft loss highlights the need for careful platform selection and antiplatelet management. These pilot data should inform adequately powered multicentre registries rather than directly change practice.

More from our Archive