Association Between End-Tidal Carbon Dioxide and Pulmonary Artery Pulse Pressure During Veno-Arterial Extracorporeal Membrane Oxygenation with Impella®: A Retrospective Exploratory Study
Hayato Shimizu, Chikara Ishino, Tomoya Ota, Naohiro Seki, Shunsuke Suzuki, Eriko Gojo, Kohei Sakagami, Miho Nagai, Junji Kakizaki, Yuta Hirano, Ken Magata, Goji Shimizu, Manato Watanabe, Yusuke Kuwahara, Chihiro KagohashiBackground: Assessment of native cardiopulmonary circulation is essential during combined veno-arterial extracorporeal membrane oxygenation (V-A ECMO) and Impella® support (ECPELLA). Pulmonary artery catheter (PAC)-derived pulmonary artery pulse pressure (PAPP) is associated with RV stroke volume and pulmonary arterial compliance; however, PAC monitoring has procedure-related risks and technical limitations. End-tidal carbon dioxide (EtCO2) is a simple, continuous, noninvasive indicator of pulmonary blood flow; however, its relationship with PAPP during ECPELLA support remains unclear. Methods: We retrospectively analyzed adult patients who underwent simultaneous ECPELLA and PAC monitoring between April 2024 and December 2025. Hemodynamic variables and EtCO2 were evaluated on ECPELLA support day 1 and on the final day of V-A ECMO support. Correlations between EtCO2 and PAPP, as well as their temporal changes during ECPELLA support, were assessed using Spearman correlation analysis. Results: Sixteen patients were included. EtCO2 showed significant positive correlations with PAPP on ECPELLA support day 1 (r = 0.63, p = 0.009), on the final day of V-A ECMO support (r = 0.67, p = 0.007), and for changes over time (ΔPAPP vs. ΔEtCO2, r = 0.76, p = 0.001). Conclusions: EtCO2 was associated with PAPP and its temporal changes during ECPELLA support. Although these findings suggest a potential role for EtCO2 in noninvasive assessment of PAPP trends, further studies in larger cohorts are needed to better characterize this relationship.