DOI: 10.1063/5.0354283 ISSN: 0003-6951

All-diamond detector with negligible degradation after ultrahigh-dose heavy-ion irradiation

Zhangcheng Liu, Yan Zhang, Yuanyang Gao, Tianqi Wang, Fei Wang, Yang Li, Zhiwei Chen, Tao Liu, Xiao Wang, Pengfei Zhang, Pengfei Wan, Jinping Ao, Chengxin Zhao

This work presents a comprehensive evaluation of an all-diamond detector under high-dose, high-energy heavy-ion irradiation. The detector was irradiated with 84Kr18+ particles with an energy of 1302 MeV to a total fluence of 1.587 × 1010 ions/cm2 and a high absorbed dose of 9.39 Mrad(C)[93.9 kGy(C)]. After irradiation, the dark current remains at an extremely low level (10−11 A at 20 V). The 222-nm photocurrent exhibits only a slight decrease, with responsivity values of 338 and 310 mA/W before and after irradiation, respectively. The device maintains stable photoresponse under periodic 222 nm illumination after irradiation. Although the NV0 defect concentration increases, as evidenced by Raman spectroscopy, leading to a modest rise in visible-light photocurrent, the rejection ratio (R222 nm/R405 nm) remains at a relatively high level (3.2 × 104 after irradiation). These findings demonstrate that the all-diamond detector possesses outstanding radiation hardness, making it a promising candidate for harsh-radiation environments such as space and nuclear applications.