DOI: 10.1177/17085381231154354 ISSN: 1708-5381

Accurate Embolization for Endoleak after F-TEVAR of Thoracic Aortic Dissection by Detachable Coils

Tianze Xu, Yi Jin, Tao Tang, Yuanhao Tong, Chen Liu, Tong Qiao, Min Zhou, Tong Yu, Wei Wang, Ming Zhang, Feng Ran, Changjian Liu, Chao Wang, Yinhuan Shi, Wendong Li, Xiaoqiang Li, Zhao Liu
  • Cardiology and Cardiovascular Medicine
  • Radiology, Nuclear Medicine and imaging
  • General Medicine
  • Surgery

Objectives

To evaluate the efficacy and clinical outcomes of accurate embolization of endoleaks after fenestrated thoracic endovascular aortic repair (F-TEVAR) for thoracic aortic dissections.

Methods

Twenty patients with endoleaks (17 type I and 3 type II) after fenestrated thoracic endovascular aortic repair (F-TEVAR) were embolized using detachable and ordinary coils. We assessed the success rate and complications of the operation, and its effects, through clinical and CT follow-up.

Results

The mean clinical follow-up duration was 25.68 ± 11.07 months (3–44 months). During follow-up, all endoleaks were completely embolized and aortic remodeling was improved. Secondary endoleaks occurred in four patients who were embolized twice. No other complications or death were reported.

Conclusion

Embolization using detachable and ordinary coils is effective and safe for the treatment of endoleaks after fenestrated thoracic endovascular aortic repair.

More from our Archive