Accuracy of an Interstitial Continuous Glucose Management System in Critically Ill Patients: A Prospective Observational Study
Marie Seret, Claire Dupuis, Vanessa Alves de Araújo, Claudio Annicchiarico, Gabriela Macedo, Caio Pinto Teixeira Araujo, Fabio Taccone, Miriam Cnop, Thomas Desaive, Vincent Uyttendaele, Jean-Charles PreiserIntroduction:
Glycemic management in the intensive care unit (ICU) remains challenging because glucose levels fluctuate rapidly and monitoring is intermittent. Interstitial continuous glucose monitoring (CGM) could improve surveillance, but its performance during rapid glucose excursions remains uncertain. We assessed the accuracy of the Dexcom G7 CGM in critically ill patients under stable conditions and during intravenous glucose tolerance tests (IVGTT).
Methods:
We conducted a prospective ancillary study of the Determination of Insulin Resistance in ICU (DIRICU) study. Twenty critically ill adults with stress hyperglycemia, no prior diabetes, and expected ICU stay ≥5 days were included. A Dexcom G7 sensor was compared with arterial blood glucose measurements. Accuracy was assessed over the first 10 ICU days using paired measurements, mean bias, mean absolute relative difference (MARD), linear regression (
Results:
Outside IVGTT, 716 paired values showed moderate agreement with reference glucose (
Conclusions:
Dexcom G7 showed acceptable accuracy during stable ICU conditions, but performance deteriorated during rapid glucose excursions. Hybrid monitoring strategies combining CGM with intermittent blood glucose confirmation may therefore be preferable in critically ill patients.