A Critical Review of Full-Scale Fire Tests and Prediction Methods for Timber–Concrete Composite Slab Floors
Jingxian Zhao, Cheng Chen, Asif Usmani, Liming JiangAbstract
With growing demand on low-carbon and fire-safe building solutions, timber–concrete composite (TCC) floors have emerged as a sustainable and efficient alternative. This paper provides a critical review of the fire performance of slab-type TCC floors, with an emphasis on studies reported in the past five years, including 25 full-scale furnace tests. Results show that cross laminated timber (CLT) concrete floors are prone to char fall-off, leading to sharp inner temperature rises and highly variable fire resistance (30–214 min), mainly influenced by load ratio, lamella thickness, and connection type. The fire resistance of slabs generally exceeded 90 min under service loads, and higher load ratios caused earlier failure. By contrast, nail-laminated timber– and laminated veneer lumber–concrete systems exhibited stable charring and consistently higher resistance (