A comparative study to evaluate the cervical spine movements during laryngoscopy using Macintosh and Airtraq laryngoscopes
Kiranpreet Kaur, Rameez Raja, Prashant Kumar, Roop Singh, Sumedha Vashishth, Harshil D. Singh, Mamta Bhardwaj, Suresh K. Singhal- Anesthesiology and Pain Medicine
- Pharmacology (medical)
- General Pharmacology, Toxicology and Pharmaceutics
Abstract
Background and Aim:
Intubation with Macintosh requires flexing the lower cervical spine and extending the atlanto-occipital joint to create a “line of sight.” Primary aim of study was to compare the extent of cervical spine movement during laryngoscopy using conventional Macintosh laryngoscope and Airtraq.
Material and Methods:
A total of 25 patients of either sex between the age group of 18 and 60 years, having American Society of Anesthesiologists (ASA) physical status of Grade-I and Grade-II, scheduled for elective surgery under image control requiring general anesthesia and intubation were enrolled. A baseline image of the lateral cervical spine including the first four cervical vertebrae was taken by an image intensifier. After administration of general anesthesia, laryngoscopy was first performed using a Macintosh laryngoscope and a second X-ray image of the lateral cervical spine was taken. The second laryngoscopy using a Airtraq laryngoscope was done and the third image of the lateral cervical spine was taken. Angles between occiput and C1; C1 and C2; C2 and C3; C3 and C4; and occiput and C4 were calculated. Atlanto-occipital distance (AOD) was calculated as the distance between occiput and C1.
Results:
Macintosh showed greater cervical movement as compared with Airtraq but a significant difference in the movement was observed at C2–C3 and C0–C4. Baseline mean AOD was 2.21 ± 1.25 mm, after Macintosh and Airtraq laryngoscopy was found to be 1.13 ± 0.60 and 1.6 ± 0.78 mm, respectively, and was found to be significant (
Conclusion:
We conclude that Airtraq allows intubation with less movement of the upper cervical spine makes Airtraq preferred equipment for intubation in patients with a potential cervical spine injury.